7.5HP Fire Pump Panel
7.5HP Fire Pump Panel

7.5HP Fire Pump Panel

MOQ : 100 Pieces

7.5HP Fire Pump Panel Specification

  • Shape
  • Rectangular Box
  • Connectivity Type
  • Hardwired electrical connections
  • Control Type
  • DOL (Direct-On-Line) Starter
  • Coating Type
  • Powder coated finish, anti-corrosive
  • Features
  • Auto & Manual Control, Fault Indications, Overload Protection, Phase Failure/Sequence Protection, Emergency Stop
  • Mounting Type
  • Wall Mount
  • Working Temperature
  • 0C to 50C
  • Coverage Area
  • Determined by installed pump and sprinkler/hydrant layout
  • Energy Efficiency Rating
  • NA (panel/control equipment)
  • Fire Class
  • Suitable for Class A, B, and C fires when integrated with matching pump
  • Voltage
  • 415V AC, 3 Phase, 50 Hz
  • Operating Pressure
  • Corresponds to system pump pressure (typically up to 10 bar)
  • Fire Extinguisher Type
  • Panel for Electric Control of Fire Pumps
  • Installation Type
  • Wall mounted
  • Technology
  • Automatic and manual operation with microprocessor-based controls
  • Application
  • Fire fighting and fire safety systems
  • Max Flow Rate
  • NA (depends on connected pump)
  • Capacity
  • Rated for 7.5HP pump control, 3-phase
  • Diameter
  • Not Applicable (Panel type equipment)
  • Pressure
  • Upto 10 bar (depends on pump)
  • Material of Construction
  • CRCA Sheet Steel
  • Panel Color
  • Red (Standard Fire Panel Color)
  • Cooling
  • Natural air ventilation
  • Display
  • LED indicators for status, faults, and operation
  • Auxiliary Supply
  • 230V AC for control circuit
  • Indications
  • Power On, Pump Running, Fault, Trip
  • Weight
  • Approximately 22 kg
  • Panel Protection
  • IP-54 / IP-55 Enclosure
  • Controls
  • Start/Stop Push Buttons, Auto/Manual Selector Switch
  • Short Circuit Protection
  • MCB/MCCB Fitted
  • Cable Entry
  • Bottom/Top entry with cable glands
  • Standards Compliance
  • IS-13947, IEC Standards
 

7.5HP Fire Pump Panel Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • Haryana, Delhi
 

About 7.5HP Fire Pump Panel



Purchase the valiant 7.5HP Fire Pump Panel-crafted from unmatchable CRCA Sheet Steel and boasting a perfect red powder-coated finish for enduring protection. Get unrivaled control with its IP-54/IP-55 enclosure, LED status indicators, and microprocessor-based DOL starter for automatic and manual operation. Engineered with rigorous IS-13947 and IEC standard compliance, this panel supports Class A, B, and C fire safety systems. With competitive pricing and robust emergency stop features, it's the ideal solution for service providers, suppliers, and traders across India.

Unmatched Features for Reliable Fire Safety

The 7.5HP Fire Pump Panel is designed for valiant fire safety applications across residential, commercial, and industrial settings. It features auto and manual control selection, clear LED fault and operation indicators, and robust short circuit as well as phase failure protection. Special features include emergency stop, bottom/top cable entry, and wall-mounting capability. Its anti-corrosive powder-coated enclosure ensures long service life, making it perfect for demanding fire fighting systems requiring unbreakable reliability.


Premium Export Market Supply & Payment Flexibility

Our 7.5HP Fire Pump Panel is available for prompt export market delivery through trusted goods transport networks. We offer a sample policy that assures product satisfaction and premium quality. Convenient payment terms are available to suit varied client needs, ensuring seamless transactions. Supply ability is robust, supporting bulk and ongoing orders for both small and large-scale fire safety projects, making us a dependable choice for traders, suppliers, and service providers in India.


FAQ's of 7.5HP Fire Pump Panel:


Q: How does the 7.5HP Fire Pump Panel enhance fire safety systems?

A: The panel controls and monitors fire pumps with automated and manual operation, ensuring rapid response to fire incidents and reducing system downtime with real-time status and fault indications.

Q: What is the process for installing the 7.5HP Fire Pump Panel?

A: Installation involves wall mounting the panel, connecting the pump and electrical supply through designated cable entries, and configuring controls for both auto and manual operation modes.

Q: Where can the 7.5HP Fire Pump Panel be used?

A: This panel is perfect for integration in residential, commercial, and industrial fire fighting systems, accommodating various sprinkler or hydrant layouts and operating reliably up to 10 bar pressure.

Q: What are the special features that set this panel apart?

A: Key features include an IP-54/IP-55 enclosure, clear LED indicators for faults and operation, emergency stop, phase failure protection, and a durable, anti-corrosive, powder-coated finish.

Q: When should the fire pump panel be switched to manual mode?

A: Manual mode is recommended during maintenance, troubleshooting, or when automatic controls need to be overridden for immediate pump operation in critical situations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Pump Panel Category

DG Fire Pump Panel

DG Fire Pump Panel

Minimum Order Quantity : 1 Piece

Fire Extinguisher Type : Not applicable (Control Panel for Fire Pump)

Installation Type : Wall Mounted / Floor Mounted

Technology : Microprocessor / Relaybased Control System

Application : Fire Protection System, Emergency Fire Fighting

Voltage : 415V AC, 3 Phase, 50 Hz Statampere (sA)

CFM Panel

CFM Panel

Minimum Order Quantity : 1 Piece

Fire Extinguisher Type : Panel Mounted Suppression

Installation Type : Wall Mounted

Technology : Automatic Fire Suppression

Application : Industrial, Commercial Fire Safety System

Voltage : 230 V AC

40HP Fire Pump Panel

40HP Fire Pump Panel

Minimum Order Quantity : 1 Piece

Fire Extinguisher Type : Pump Starter Panel (not direct extinguisher)

Installation Type : Wall Mounted

Technology : Microprocessorbased

Application : Fire Fighting System Control

Voltage : 415V AC, 3 Phase

Diesel Pump Panel

Diesel Pump Panel

Minimum Order Quantity : 100 Pieces

Fire Extinguisher Type : Panel for Fire Diesel Pumps

Installation Type : Wall Mounted / Floor Standing

Technology : Microprocessor Based Automatic Control

Application : Diesel Pump Operation & Control

Voltage : 415 V AC, 50 Hz